Incremental position point-to-point profile, Velocity motion profile – Rockwell Automation 2097-Vxxx Kinetix 300 EtherNet/IP Indexing Servo Drive User Manual User Manual

Page 196

Advertising
background image

196

Rockwell Automation Publication 2097-UM001D-EN-P - November 2012

Appendix B

Input and Output Assembly

Incremental Position Point-to-Point Profile

To execute an incremental position move, set these tag values as shown.

Table 76 - Output Assembly Tags

Velocity Motion Profile

To execute a velocity move, set these tag values as shown.

Table 77 - Output Assembly Tags

RSLogix 5000 Tags

Value

ReferenceSource

Set value to 2.

CommandPosition

Configure the motion profile by setting tags to the desired values.

VelocityLimit

AccelerationLimit

DecelerationLimit

DriveEn

Enable the drive by turning tag on.

StartMotion

Start profile by turning tag on.

ID Tag

RSLogix 5000 Tags

Value

N/A

ReferenceSource

Set value to 1.

N/A

CommandCurrentOrVelocity

Set the velocity value.

75

(1)

Enable Accel/Decel function/limits for
Velocity mode

Use internal defaults for Accel/Decel (ID 75 set to 0 = Disable).
Set Accel/Decel values by writing to ID 76 and 77 by using explicit

messaging (See Appendix D on

page 211

). Tag 75 must be set to 1 =

Enabled, for the values to be used.

76

(1)

Accel value for Velocity mode

77

(1)

Decel value for Velocity mode

N/A

DriveEn

Enable the drive by turning tag on.

(1) You can also set these parameters by using MotionView software, General category>Velocity Mode Acceleration.