PRG V676 User Manual 3.5 User Manual

Page 224

Advertising
background image

206

V676

®

/ V476

®

CONTROL CONSOLE USER MANUAL

When

Time

is selected, this number will be the length of time, in seconds, that the effect will run before initiating

its Fade Out.

Note: If "N/A" is selected as the Duration attribute, then this value will not be used.

+

Zero State Fade - While a channel is fading to a Zero State and another cue is executed with an Out Time

before

the Zero State finishes its fade, the Zero State channels will now continue to use the Zero State time. The
following diagrams represents the new action:

+

Step - The time between activation of a sequence step and the next sequential step. On an effects level, Step
Time can be used in two ways: either to set all sequence steps to the same timing value or to scale the timing
values of sequence steps (when sequence steps have different timing values already stored). Step times can also
be set individually (refer to

"Assigning Timing Values"

on page 208) or scaled by turning the encoder. The step

time shown is that of the last step.

100

Zero State

Another Cue executed

This cue is ignored

10 Second Fade

and fade continues
to Zero State

- go to Out State in 0 time

Cue executed
- fade to Zero State in 10 seconds