Analog-to-Digital Converter (ADC)

MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2

26-32

Freescale Semiconductor

26.5.7

Interrupt Sources

Figure 26-24

illustrates how five interrupt sources are combined into three entries in the interrupt vector

table.

Figure 26-24. ADC Interrupt Sources

26.5.8

Power Management

The five supported power modes are described below. They are in order of highest to lowest power
utilization at the expense of increased conversion latency and/or startup delay. Please see

Section 26.5.9,

“ADC Clock

,” for details of the various clocks referenced below.

26.5.8.1

Power Management Modes

1. Normal power mode

This mode operates when:

— At least one ADC converter is powered up (PD0 or PD1=0 in the POWER register);

— Auto power-down and auto standby modes are disabled (APD=0, ASB=0 in the POWER

register);

— The ADC’s clock is enabled (ADC=1 in the SIM module’s SIM_PCE register).

In this mode, the ADC uses the conversion clock as the ADC clock source when active or idle. To
minimize conversion latency, it is recommended the conversion clock be configured to 5.0 MHz. No
startup delay (defined by PUDELAY in the POWER register) is imposed.

2. Auto power-down mode

This mode operates when:

— At least one ADC converter is powered up (PD0 or PD1=0 in the POWER register);

— Auto power-down mode is enabled (APD=1 in the POWER register);

— The ADC’s clock is enabled (ADC=1 in the SIM module’s SIM_PCE register).

Auto power-down and standby modes can be used together by setting APD equal to 1 in the above
configuration. This hybrid mode converts at an ADC clock rate of 100 kHz using standby current mode
when active, and gates off the ADC clock and powers down the converters when idle. A startup delay of

EOSI0

EOSIE0

EOSI1

EOSIE1

ZCI

ZCIE

ADC Zero Crossing or Limit Error

LLMTIE

HLMTI

HLTMIE

LLMTI

(ADC_ERR_INT)

ADCB Conversion Complete
(ADC_CC1_INT)

ADCA Conversion Complete
(ADC_CC0_INT)