Memory Map/Register Definition

MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2

Freescale Semiconductor

11-5

11.2.1.3

RTC Hours and Minutes Alarm Register (ALRM_HM)

The real-time clock hours and minutes alarm (ALRM_HM) register is used to configure the hours and
minutes setting for the alarm. The alarm settings can be read or written at any time.

Figure 11-4. RTC Hours and Minutes Alarm Register (ALRM_HM)

IPSBAR

Offset: 0x03C8 (ALRM_HM)

Access: User read/write

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

R

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

W

Reset

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

R

0

0

0

HOURS

0

0

MINUTES

W

Reset

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Table 11-4. ALRM_HM Field Descriptions

Field

Description

31–13

Reserved, should be cleared.

12–8

HOURS

Alarm hour setting; can be set to any value between 0 and 23.

7–6

Reserved, should be cleared.

5–0

MINUTES

Alarm minute setting; can be set to any value between 0 and 59.

Advertising