Clock Module

MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2

Freescale Semiconductor

6-27

SCM

1

0

0

On On 1

SCM

0

0

1

Lose reference
clock

SCM

Note:

PLL = PLL enabled during STOP mode. PLL = On when STPMD[1:0] = 00 or 01

OSC = oscillator enabled during STOP mode. Oscillator is on when STPMD[1:0] = 00, 01, or 10

MODES

NRM = normal PLL crystal clock reference or normal PLL external reference mode. During normal external reference mode,

the oscillator is never enabled. Therefore, during these modes, refer to the OSC = On case regardless of STPMD values.

EXT = external clock mode

REF = PLL reference mode due to losing PLL clock or lock from NRM mode

SCM = PLL self-clocked mode due to losing reference clock from NRM mode

RESET = immediate reset

LOCKS

‘LK -= expecting previous value of LOCKS before entering stop

0–>‘LK = current value is 0 until lock is regained which then is the previous value before entering stop

0–> = current value is 0 until lock is regained but lock is never expected to regain

LOCS

‘LC = expecting previous value of LOCS before entering stop

1–>‘LC = current value is 1 until clock is regained which then is the previous value before entering stop

1–> = current value is 1 until clock is regained but CLK is never expected to regain

Table 6-19. Stop Mode Operation (continued)

MODE

In

LO

CEN

LOCRE

LO

LRE

PLL

OSC

FWKUP

Expected

PLL

Action at

Stop

PLL Action

During Stop

MODE

Out

LOCKSS

LO

CK

LO

CS

Comments