2 control 2 register (ctrl2), 2 control 2 register (ctrl2) -5, 1 ctrl2 under sequential scan modes – Freescale Semiconductor ColdFire MCF52210 User Manual

Page 441

Advertising
background image

Analog-to-Digital Converter (ADC)

MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2

Freescale Semiconductor

26-5

26.4.2

Control 2 Register (CTRL2)

The structure of the CTRL2 register depends on whether the ADC is operating in sequential or parallel
mode (see

Section 26.4.1, “Control 1 Register (CTRL1)

”).

26.4.2.1

CTRL2 Under Sequential Scan Modes

7–4

CHNCFG

Channel Configure. This field configures the inputs for single-ended or differential conversions:

2–0

SMODE

Scan Mode Control. This field controls the scan mode of the ADC module. See

Section 26.5.6, “Scan

Configuration and Control

” for details on each scan mode.

000 Once sequential
001 Once parallel
010 Loop sequential
011 Loop parallel
100 Triggered sequential
101 Triggered parallel (default)
110 Reserved; do not use
111 Reserved; do not use

IPSBAR

Offset:


0x19_0002 (CTRL2)

Access: read/write

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

R

0

0

0

0

0

0

0

0

0

0

0

DIV

W

Reset

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

0

Figure 26-3. Control 2 Register (CTRL2) Under Sequential Scan Modes

Table 26-2. CTRL1 Field Descriptions (continued)

Field

Description

CHNCFG

Inputs

Description

xxx1

AN0–AN1

Configured as differential pair (AN0 is + and AN1 is –)

xxx0

Both configured as single ended inputs

xx1x

AN2–AN3

Configured as differential pair (AN2 is + and AN3 is –)

xx0x

Both configured as single ended inputs

x1xx

AN4–AN5

Configured as differential pair (AN4 is + and AN5 is –)

x0xx

Both configured as single ended inputs

1xxx

AN6–AN7

Configured as differential pair (AN6 is + and AN7 is –)

0xxx

Both configured as single ended inputs

Advertising