Freescale Semiconductor ColdFire MCF52210 User Manual

Page 59

Advertising
background image

ColdFire Core

MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2

Freescale Semiconductor

3-15

fixed-length stack frame for all exceptions. The exception type determines whether the program
counter placed in the exception stack frame defines the location of the faulting instruction (fault)
or the address of the next instruction to be executed (next).

4. The processor calculates the address of the first instruction of the exception handler. By definition,

the exception vector table is aligned on a 1 Mbyte boundary. This instruction address is generated
by fetching an exception vector from the table located at the address defined in the vector base
register. The index into the exception table is calculated as (4

× vector number). After the exception

vector has been fetched, the vector contents determine the address of the first instruction of the
desired handler. After the instruction fetch for the first opcode of the handler has initiated,
exception processing terminates and normal instruction processing continues in the handler.

All ColdFire processors support a 1024-byte vector table aligned on any 1 Mbyte address boundary (see

Table 3-5

). The table contains 256 exception vectors; the first 64 are defined for the core and the remaining

192 are device-specific peripheral interrupt vectors. See

Chapter 14, “Interrupt Controller Module”

for

details on the device-specific interrupt sources.

Table 3-5. Exception Vector Assignments

Vector

Number(s)

Vector

Offset (Hex)

Stacked

Program

Counter

Assignment

0

0x000

Initial supervisor stack pointer

1

0x004

Initial program counter

2

0x008

Fault

Access error

3

0x00C

Fault

Address error

4

0x010

Fault

Illegal instruction

5

0x014

Fault

Divide by zero

6–7

0x018–0x01C

Reserved

8

0x020

Fault

Privilege violation

9

0x024

Next

Trace

10

0x028

Fault

Unimplemented line-A opcode

11

0x02C

Fault

Unimplemented line-F opcode

12

0x030

Next

Debug interrupt

13

0x034

Reserved

14

0x038

Fault

Format error

15–23

0x03C–0x05C

Reserved

24

0x060

Next

Spurious interrupt

25–31

0x064–0x07C

Reserved

32–47

0x080–0x0BC

Next

Trap # 0-15 instructions

48–63

0x0C0–0x0FC

Reserved

Advertising