2 rtc seconds counter register (seconds) – Freescale Semiconductor ColdFire MCF52210 User Manual

Page 164

Advertising
background image

Real-Time Clock

MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2

11-4

Freescale Semiconductor

11.2.1.2

RTC Seconds Counter Register (SECONDS)

The real-time clock seconds register (SECONDS) is used to program the seconds for the TOD clock. It
can be read or written at any time. After a write, the time changes to the new value. A power-on reset
(POR) sets the RTC to the reset values shown in

Figure 11-3

.

Figure 11-3. RTC Seconds Counter Register (SECONDS)

IPSBAR

Offset: 0x03C4 (SECONDS)

Access: User read/write

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

R

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

W

Reset

1

1

After power-on reset (POR)

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

R

0

0

0

0

0

0

0

0

0

0

SECONDS

W

Reset

0

0

0

0

0

0

0

0

0

0

?

?

?

?

?

?

Table 11-3. SECONDS Field Descriptions

Field

Description

31–6

Reserved, should be cleared.

5–0

SECONDS

Seconds setting; can be set to any value between 0 and 59.

Advertising
This manual is related to the following products: