Analog-to-Digital Converter (ADC)

MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2

26-18

Freescale Semiconductor

5. Current mode

Normal current mode is used to power the converters at clock rates above 100 kHz.

Standby current mode uses less power and is engaged only when the ADC clock is at 100 kHz. The
current mode active does not affect the number of ADC clock cycles required to do a conversion
or the accuracy of a conversion. The ADC module may change the current mode when idle as part
of the power saving strategy. Both converters are in the same current mode at all times.

In addition to the power modes, there is startup delay:

Auto power-down and auto standby power modes cause a startup delay when the ADC module
goes between the idle and active states to allow time to switch clocks or power configurations. The
number of ADC clocks used in the startup delay is defined by the PUDELAY field.

See the discussion of power modes in the Functional Description

Section 26.5, “Functional Description

for details of the 5 power modes and how to configure them. See

Section 26.5.9, “ADC Clock

,” for a more

detailed description of the clocking system and the control of current mode.

IPSBAR

Offset: 0x19_0052 (POWER)

Access: read/write

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

R

ASB

0

0

PSTS2 PSTS1 PSTS0

PUDELAY

APD

PD2

PD1

PD0

W

Reset

0

0

0

0

0

0

0

0

1

1

0

1

0

1

1

1

Figure 26-16. Power Control Register (POWER)

Table 26-18. POWER Field Descriptions

Field

Description

15

ASB

Auto Standby bit. This bit selects auto standby mode. ASB is ignored if APD is set. When the ADC is idle,
auto standby mode selects the standby clock as the ADC clock source and puts the converters into standby
current mode. At the start of any scan, the conversion clock is selected as the ADC clock and a delay of
PUDELAY ADC clock cycles is imposed for current levels to stabilize. After this delay, the ADC initiates the
scan. When the ADC returns to the idle state, the standby clock is again selected and the converters revert
to the standby current state.
0 Auto standby mode disabled
1 Auto standby mode enabled

14–13

Reserved, should be cleared.

12

PSTS2

Voltage Reference Power Status bit.
0 Voltage reference circuit is currently enabled
1 Voltage reference circuit is currently disabled

11

PSTS1

Converter B Power Status bit. This bit is asserted immediately after PD1 is set. It is deasserted PUDELAY
ADC clock cycles after PD1 is cleared if APD is 0. This bit can be read as a status bit to determine when the
ADC is ready for operation. During auto power-down mode, this bit indicates the current powered state of
converter B.
0 ADC converter B is currently enabled
1 ADC converter B is currently disabled

Advertising