NOTE

DUMP

does not check for a valid address; it is a valid command only when

preceded by

NOP

,

READ

, or another

DUMP

command. Otherwise, an illegal

command response is returned.

NOP

can be used for intercommand padding

without corrupting the address pointer.

The size field is examined each time a

DUMP

command is processed, allowing the operand size to be

dynamically altered.

Command/Result Formats:

Command Sequence:

Figure 28-27.

DUMP

Command Sequence

Operand Data:

None

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Byte

Command

0x1

0xD

0x0

0x0

Result

X

X

X

X

X

X

X

X

D[7:0]

Word

Command

0x1

0xD

0x4

0x0

Result

D[15:0]

Longword

Command

0x1

0xD

0x8

0x0

Result

D[31:16]

D[15:0]

Figure 28-26.

DUMP

Command/Result Formats

XXX

’NOT READY’

DUMP (B/W)

???

XXX

’ILLEGAL’

NEXT CMD

’NOT READY’

NEXT CMD

’NOT READY’

READ

MEMORY

LOCATION

XXX

BERR

NEXT CMD

RESULT

XXX

’NOT READY’

DUMP (LONG)

???

XXX

’ILLEGAL’

NEXT CMD

’NOT READY’

NEXT CMD

’NOT READY’

READ

MEMORY

LOCATION

XXX

BERR

NEXT CMD

MS RESULT

NEXT CMD

LS RESULT