3 concurrent resets, 3 concurrent resets -9 – Freescale Semiconductor ColdFire MCF52210 User Manual

Page 159

Advertising
background image

Reset Controller Module

MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2

Freescale Semiconductor

10-9

10.6.2.1

Synchronous Reset Requests

In this discussion, the references in parentheses refer to the state numbers in

Figure 10-4

. All cycle counts

given are approximate.

If the external RSTI signal is asserted by an external device for at least four rising CLKOUT edges (3) and
if software requests a reset, the reset control logic latches the reset request internally and enables the bus
monitor (5). When the current bus cycle is completed (6), RSTO is asserted (7). The reset control logic
waits until the RSTI signal is negated (8) and for the PLL to attain lock (9, 9A) before waiting 512
CLKOUT cycles (1). The reset control logic may latch the configuration according to the RCON signal
level (11, 11A) before negating RSTO (12).

If the external RSTI signal is asserted by an external device for at least four rising CLKOUT edges during
the 512 count (10) or during the wait for PLL lock (9A), the reset flow switches to (8) and waits for the
RSTI signal to be negated before continuing.

10.6.2.2

Internal Reset Request

If reset is asserted by an asynchronous internal reset source, such as loss of clock (1) or loss of lock (2),
the reset control logic asserts RSTO (4). The reset control logic waits for the PLL to attain lock (9, 9A)
before waiting 512 CLKOUT cycles (1). Then the reset control logic may latch the configuration
according to the RCON pin level (11, 11A) before negating RSTO (12).

If loss of lock occurs during the 512 count (10), the reset flow switches to (9A) and waits for the PLL to
lock before continuing.

10.6.2.3

Power-On Reset/Low-Voltage Detect Reset

When the reset sequence is initiated by power-on reset (0), the same reset sequence is followed as for the
other asynchronous reset sources.

10.6.3

Concurrent Resets

This section describes the concurrent resets. As in the previous discussion, references in parentheses refer
to the state numbers in

Figure 10-4

.

10.6.3.1

Reset Flow

If a power-on reset or low-voltage detect condition is detected during any reset sequence, the reset
sequence starts immediately (0).

If the external RSTI pin is asserted for at least four rising CLKOUT edges while waiting for PLL lock or
the 512 cycles, the external reset is recognized. Reset processing switches to wait for the external RSTI
pin to negate (8).

If a loss-of-clock or loss-of-lock condition is detected while waiting for the current bus cycle to complete
(5, 6) for an external reset request, the cycle is terminated. The reset status bits are latched (7) and reset
processing waits for the external RSTI pin to negate (8).

Advertising