3 zero crossing control register (adzcc) – Freescale Semiconductor ColdFire MCF52210 User Manual

Page 444

Advertising
background image

Analog-to-Digital Converter (ADC)

MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2

26-8

Freescale Semiconductor

26.4.3

Zero Crossing Control Register (ADZCC)

The ADC zero crossing control (ADZCC) register provides the ability to monitor the selected channels
and determine the direction of zero crossing triggering the optional interrupt. Zero crossing logic monitors
only the sign change between current and previous sample. The ZCE0 bit monitors the sample stored in
ADRSLT0, ZCE1 bit monitors ADRSLT1, and ZCE7 bit monitors ADRSLT7. When the zero crossing is
disabled for a selected result register, sign changes are not monitored or updated in the ADZCSTAT
register.

26.4.4

Channel List 1 and 2 Registers (ADLST1 and ADLST2)

The channel list register contains an ordered list of the analog input channels to be converted when the next
scan is initiated. If all samples are enabled in the ADSDIS register, a sequential scan of inputs proceeds in
order of SAMPLE0 through SAMPLE7. If one of the parallel sampling modes is selected instead, the
converter A sampling order is SAMPLE0-3, and the converter B sampling order is SAMPLE4-7.

In sequential modes, the sample slots are converted in order from SAMPLE0 to SAMPLE7. Analog input
pins can be sampled in any order, including sampling the same input pin more than once.

In parallel modes, converter A processes sample slots SAMPLE0 through SAMPLE3, while converter B
processes sample slots SAMPLE4 through SAMPLE7. Because converter A only has access to analog
inputs AN0 through AN3, sample slots SAMPLE0-3 should only contain binary values between 000 and
011. Likewise, because converter B only has access to analog inputs AN4 through AN7, sample slots

11111

64

100 kHz

62.5 kHz

500 kHz

CLK/128

IPSBAR

Offset: 0x19_0004 (ADZCC)

Access: read/write

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

R

ZCE7

ZCE6

ZCE5

ZCE4

ZCE3

ZCE2

ZCE1

ZCE0

W

Reset

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Figure 26-5. Zero Crossing Control Register (ADZCC)

Table 26-6. ADZCC Field Descriptions

Field

Description

15–0

ZCEn

Zero Crossing Enable. For each channel n, setting the ZCEn field allows detection of the indicated zero
crossing condition, provided the corresponding offset register (ADOFSn) has a value offset, 0 < offset <
0x7FF8.
00 Zero crossing disabled
01 Zero crossing enabled for positive to negative sign change
10 Zero crossing enabled for negative to positive sign change
11 Zero crossing enabled for any sign change

Table 26-5. ADC Clock Frequency for Various Conversion Clock Sources (continued)