<E Specifications Common to FieldMate Basic and Advance>

E-51

IM 01R01A01-01E

9th Edition : May 31, 2013-00

Color of Parameter Values

Table E-3-14

Color

Explanation

No color

Indicates that the parameter values in the Device Values area and Work area are the

same.

Magenta

Indicates that for writable parameters there is a difference between the values in the

Device Values area and Work area. (Note that this does not indicate that the parameters

are targeted to be downloaded.) If even one of the parameters in the tab is in magenta, the

magenta symbol ■ is displayed beside the tab name.

Yellow

Indicates that for read-only parameters there is a difference between the values in the

Device Values area and Work area. If even one of the parameters in the tab is in yellow, the

yellow symbol ■ is displayed beside the tab name.

Orange

Indicates that for writable parameters there is a difference between the values on the

left and right of the screen. I.e. It indicates difference between the connected device and

imported files. If even one of the parameters in the tab is in orange, the orange symbol ■ is

displayed beside the tab name.

Red

Indicates that for writable parameters there is error found on the right screen, including not

only key in by user but data of imported files.

If even one of the parameters in the tab is in red, the red symbol ■ is displayed beside the

tab name.

Green

Indicate the parameter properties difference between the values in the Device Values area

and Work area.

Due to DD structure, parameter properties i.e. (Edit Format, Display Format, EnumList,

Validity, ReadOnly/WriteOnly/ReadWrite etc) are changed.

If even one of the parameters in the tab is in green, the green symbol ■ is displayed beside

the tab name.

Checkboxes beside Parameters

Checkboxes are only displayed for writable parameters. If checkmarks are added to the

checkboxes, the corresponding parameters are written to the device in the order that they are

displayed in the window when the Download Checked Parameters command is executed.
If a parameter-value display area in the Work area changes from its original color to magenta, a

checkmark is also added to the checkbox.

In other words, immediately after the parameters are loaded into the Work area when File or

Database is selected, checkmarks are added to the checkboxes of all writable parameters for

which there is a difference between values in the Work area and Device Values area. That is, all

parameters indicated in magenta.

Furthermore, when a value is edited in the window and the parameter-value display area

changes from its original color to magenta, a checkmark is also added to the checkbox.