E-63, Exporting trend data: file export – Yokogawa FieldMate User Manual
Page 113

<E Specifications Common to FieldMate Basic and Advance>
E-63
IM 01R01A01-01E
9th Edition : May 31, 2013-00
(3) Resuming trend operation
Trend graph: Continues
Internal buffer storage: Continues
(4) Switching from Trend Information tab Diagnostic Information tab Trend Information tab
Trend graph: Continues
Internal buffer storage: Continues
Exporting Trend Data: File Export
Device Viewer’s menus and tool buttons allow trend data to be exported.
The following shows the default settings.
Save location folder (FieldMate installation folder): \FM\Temp\
Folder name: TrenData_DeviceTagName_YYYYMMDD (where DeviceTagName is the device
tag of the measuring device that was started, YYYY is the year, MM is the month, and DD is the
day)
File type: CSV format, TSV format
Each line of the file content is exported in the following order.
Time stamp, trend point name, and acquisition data value
E040205E.ai
Figure E-4-7
Trend Data Export Example