F-40, Menu – Yokogawa FieldMate User Manual

Page 159

Advertising
background image

<F Advance>

F-40

IM 01R01A01-01E

9th Edition : May 31, 2013-00

• When selecting Database, data selection screen is displayed. Available selections are

parameters saved in the database of the device, which is the same model as the relevant

device, in the past.

In dialog selection, Date & Time, Device Tag, Device ID, and Reason are shown in table

format.

With Device ID that is the same as the relevant device, the latest line of Date & Time is

focused by default.

• When selecting File, a list of files is displayed to select and execute.

Menu

Table F-3-1

Menu

Description

File

Save Custom TAB Info

Saves the parameters to Custom tab.

Exit

Exits Parameter Manager.

Edit

Find Parameters…

Searching parameters, including strings input by user, among tabs in

display.

Undo Modifications

As for tabs in display, returns changes with the right part of screen.

View

Show Read Only Parameters

By Checking, Read Only Parameter is displayed. Default is ON. If it is

off, only Write-enabled Parameter can be displayed while Read Only

Parameter is not displayed. In addition, yellow indicating difference of

Read Only Parameters (including tab title) is not displayed.

Tool Bar

Checking this enables you to select the Show/Hide option for the tool bar. It

is selected by default (the tool bar is shown).

Result Area

Checking this enables you to select the Show/Hide option for the Result

area in the lower part of the screen. It is selected by default (the Result

area is shown).

Status Bar

Checking this enables you to select the Show/Hide option for the status

bar. It is selected by default (the status bar is shown).

Sorting Order ->

By Device Values

By Device Valves 1

It is effective only when files are loaded in the right part of the screen.

Parameters are displayed in the order defined by device DD. (*1)

Sorting Order ->

By Work Area

By Device Valves 2

It is effective only when files are loaded in the right part of the screen.

Parameters are displayed in the order defined by files. (*1)

Mode -> Actual Device

Switches to Device mode.

Mode -> Database Device

Switches to Database mode.

Action Update Device Values – Current TAB

(F2)

Loads parameter values in the tab during the display and updates the

left part of the screen. The right part of the screen is not updated.

Update Device Values – All TAB (F5)

The procedures above are executed in all the tabs.

Update Device Values and Attributes -

All TAB (F1)

Obtains all the parameter lists and attributes (including unit information)

of the connected device and loads all the parameter values to update

the left part of the screen of all the tabs. The right part of the screen is

not updated.

Download Checked Parameters -

Current TAB (F3)

As for parameters whose Download Checked Parameters checkboxes

are checked in the tab in display, the left part of the screen is updated

by executing read-back with only the written parameters after writing

the device in the order displayed on the screen.

If download has been succeeded, indication of magenta is returned to

the normal indication.

Download Checked Parameters - All

TAB (F6)

The procedures above are executed in all the tabs.

Save/Export Device Values…

Parameter values of the device (the left part of the screen) are exported

to the file or saved in the database. (Only shown in Device mode)

Copy Device Values to Work Area

Parameter values of the device (the left part of the screen) are copied

to the right part of the screen. (Only shown in Device mode)

Save/Export Work Area…

Parameter values of the right part of the screen are exported to the file

or saved in the database. (Only shown in Device mode)

Load/Import to Work Area…

Loads parameter values from file/database and displays on the right

part of the screen. (Only shown in Device mode)

*

1

Effective for FOUNDATION fieldbus only.