Outline, Operation to import type b dtm data to type c dtm – Yokogawa FieldMate User Manual
Page 382

<Appendix K Importing Type B Yokogawa DTM Data to Type C Yokogawa DTM>
App.-61
IM 01R01A01-01E
9th Edition : May 31, 2013-00
Appendix K Importing Type B Yokogawa
DTM Data to Type C
Yokogawa DTM
Outline
In the Offline Parameter Display on DTM Works, you must select the FDT version to import Type
B DTM data to Type C DTM, depending on the device models and DTM revisions. The following
is an example to import Type B DTM data to Type C DTM.
App.K01E.ai
Menu to import Type C DTM data
Menu to import Type B DTM data
Figure App.-K- Importing Type B DTM Data to Type C DTM
Operation to import Type B DTM Data to Type C DTM
1. After Type C DTM is started on DTM Works, select [Import from file].
2. If Type B DTM data file exists in the database, the “Import Option” window appears to select
Type B or Type C DTM. (The File Selection window appears if there are no Type B DTM
data files in the database.)
Select [Import from the previous version DTM data] to select a Type B DTM data file.
3. If [Import from the previous version DTM data] is selected in the previous operation, the list
of available Type B DTM data files appears. Select the data file that you want to import, and
click [OK].