F-5-2 User Defined Connection

Built-in Connection supports the communication paths for HART, FOUNDATION

fieldbus, PROFIBUS, BRAIN and ISA100 direct connections. If you want to build a

communication path other than the HART, FOUNDATION fieldbus, PROFIBUS, and BRAIN

direct connections that are supported in Built-in Connection, you can use User Defined

Communication. If you want to use a communication protocol that is not supported

in Built-in Communication, you can also use User Defined Connection. If you want to

create a communication path and register a device using User Defined Connection, you

need to separately obtain and install the Comm DTM, Gateway DTM, Device DTM, or a

communication interface card if needed.

UDC Mode Window

An FDT Project is composed of a network topology of Comm DTM, Gateway DTM, and Device

DTM defined in DTM Works, and DTM data set for each DTM. The following shows the overview

of the FDT Project.

F050201E.ai

The Update button

refreshes the

information of the device

that is connected to the

currently displayed FDT

segment. The display is

updated.
Selecting this displays

nothing in the right panel.

Click this to open DTM

Works and create a new

FDT project.

Expand a project and

select a Comm DTM to

display the device DTM in

the right panel.

Icons that indicate Device

Flag or Memo Flag may

be displayed for devices

that are registered in the

database.

A red exclamation mark (!) is shown for devices

that are not registered in the database.

Displays either the live tag

of the device or the

configured device tag in

DTM Works.

Icons corresponding to the devices are

displayed. When there is no corresponding

icon, one of the following icons indicating

the communication type is displayed.

Communication status

is displayed.

Device information

is displayed.

Indicates the self-diagnostic result of only HART devices.

For other devices, there is no indication.

(Yellow): Warning, configuration error. Operation continues.

(Green): Normal

(Red): Abnormal, needs inspection (including replacing devices).
(Gray): Communication error, etc.
(White): Display of status icon is set to OFF.

Figure F-5-9

UDC Mode Window

The following describes the outline of the procedure for how to use User Defined Connection.

1. Install the Comm DTM, Gateway DTM, Device DTM, and a communication interface card

on a PC installed with FieldMate.

2. Update the DTM catalog in DTM Setup. *
3. Select User Defined Connection in Segment Viewer. Start DTM Works by selecting New

FDT Project.

4. Select and assign the Comm DTM and Gateway DTM from the list of installed Comm

DTMs, Gateway DTMs, and Device DTMs.

5. Configure the Comm DTM and Gateway DTM to create a communication path.
6. Select the Device DTM and assign the device.