Homing 6 – Lenze 931E/K Small Drives Control User Manual

Page 102

Advertising
background image

Homing

6

l

102

SW−HB 13.0002−EN 4.1

Mode −2: Positive limit stop with zero pulse evaluation

With this mode, the drive traverses in positive direction until reaching the limit stop. The
931E servo positioning controller needs at least 1 second to detect the limit stop. When
selecting the limit stop, ensure that it will not be damaged when the maximum current
parameterised will be applied. The zero position refers to the first zero pulse of the angle
encoder in negative direction from the limit stop.

-2

931E_108

Fig. 24

Homing to the positive limit stop with zero pulse evaluation

0 Zero pulse

Mode −17: Homing to the negative limit stop

With this mode, the drive traverses in negative direction until reaching the limit stop. The
931E servo positioning controller needs at least 1 second to detect the limit stop. When
selecting the limit stop, ensure that it will not be damaged when the maximum current
parameterised will be applied. The zero position directly refers to the limit stop.

-17

931E_109

Fig. 25

Homing to the negative limit stop