Digital outputs and analog inputs and outputs

Digital outputs DOUT1, DOUT2

7

l

107

SW−HB 13.0002−EN 4.1

Settings

Select the menu Parameters

W I/Os W Digital outputs to set the parameters of the digital

outputs DOUT1 and DOUT2.

931e_318

DOUT1 and DOUT2 can each be independently assigned with one of the following signals:

ƒ

OFF, i.e. output inactive, LOW level via integrated pull−down resistor

ƒ

ON, i.e. output active, 24 V HIGH level via integrated high−side switch

ƒ

Power stage active, i.e. power stage switched on

ƒ

I

@T message motor / servo

ƒ

Group warning

ƒ

Group error message

ƒ

Following error

ƒ

Remaining path message

ƒ

Target reached

ƒ

Homing completed

ƒ

Comparison speed reached

ƒ

Course program

With some selections, there is a button with three points behind the selection box. If you
click this button, a window opens in which you can enter additional settings.

Setting the messages for the digital outputs

When used together with a control, it may be useful in many applications that the servo
positioning controller generates a message, if the selected operating conditions are not
complied with or not reached. Select the menu item Parameters

W Messages to open the

window for setting the messages. Here, you can select the tolerance margins for the
messages "Comparison speed reached", "Target reached" and "Following error".