Appendix – Lenze 931E/K Small Drives Control User Manual

Page 178

Advertising
background image

Appendix

Timing charts
Switch−on sequence

10

l

178

SW−HB 13.0002−EN 4.1

ƒ

t1

≈ 500 msec

Boot−program processing and start of application

ƒ

t2 > 1.6 msec

ƒ

t3

≈ 10 msec

Depends on the operating mode and the status of the drive

ƒ

t4 = N x 1.6 msec
Parameterisable (brake parameter for run delay t

F

)

ƒ

t5 < 1.6 msec

ƒ

t6 = N x 0.2 msec
Depends on the quick stop ramp

ƒ

t7 = N x 1.6 msec
Parameterisable (brake parameter for stop delay t

A

)

Advertising