Communication object list
Bit assignment of command word / status word / error word

10

l

172

SW−HB 13.0002−EN 4.1

10.4.2

Bit assignment of command word / status word / error word

Command word (seqc_opmode)

Bit

Meaning

31

Controller reset (hardware reset via commh)

30

Debug mode 0 = off; 1= on

29

˙

28

Load default parameters from program memory (init!)

27 ... 19

˙

18

Setpoint inhibit (activated inside the controller)

17

Direction bit 0 = CCW rotation, 1 = CW rotation (inverts both speed setpoints and position
setpoints); if torque control is activated, also inverts the torque setpoints

16

Error acknowledgement

18

Setpoint inhibit (activated inside the controller)

17

Direction bit 0 = CCW rotation, 1 = CW rotation (inverts both speed setpoints and position
setpoints); if torque control is activated, also inverts the torque setpoints

16

Error acknowledgement

15 ... 13

˙

12

Start positioning or homing

11

˙

10

Reversal of direction of rotation (inverted direction of rotation for identical setpoints)

9 ... 7

˙

6

Activate sub−mode synchronous positioning

5

Activate homing

4

Activate positioning

3

Activate speed control

2

Activate torque control

1

Activate position control

0

Controller enable