Troubleshooting and fault elimination, Error message – Lenze 931E/K Small Drives Control User Manual

Page 128

Advertising
background image

Troubleshooting

and fault elimination

Error message

9

l

128

SW−HB

13.0002−EN 4.1

Remedy

Cause

Response

Activation
time

Meaning

CAN error
code

Error No.

Remedy

Cause

O

W

H

A

Activation
time

Meaning

CAN error
code

Error No.

28

4280

Power stage
temperature 5

°C

below maximum

< 100 ms

ю ю ю ¨ Temperature rise of the 931E/K

l

Check power dimensioning of the drive system.

l

Check / improve mounting and cooling conditions

29

8611

Following error
monitoring

< 5 msec

ю ю ю ¨ Motor is blocked

l

Optimise controller setting to improve the
smooth running characteristics.

l

Adapt traversing profile (e.g. reduce acceleration
and deceleration ramps.

l

Increase following error margin/message delay.

31

8612

Limit switch error

< 1 ms

ю ю ю ¨

l

Incorrect wiring of limit switch

l

Limit switch defective

l

Ensure correct wiring of limit switch.

l

Replace limit switch

l

Check limit switch configuration.

35

6199

Time−out with quick
stop

< 5 msec

þ ¨ ¨ ¨

l

Angle encoder error

l

Motor identification has not been
successful

l

Selected acceleration is too high

36

8A80

Homing error

< 5 msec

ю ю ю ¨

l

Homing could not be completed
successfully.

l

Controller parameterisation and angle
encoder setting are not OK

l

Check configuration of homing.

l

Change controller parameterisation and angle
encoder setting

40

6197

Error: Motor and angle
encoder identification

< 5 msec

þ ¨ ¨ ¨

l

Homing could not be completed
successfully.

l

Controller parameterisation and angle
encoder setting are not OK

l

Check resolver plug connection.

l

Check resolver cable for cable breakage, short
circuit.

l

Check pin assignment of resolver cable plug.

l

Correct encoder parameters.

43

6193

Course program:
Unknown command

< 5 msec

ю ю ¨ ¨

Please contact the Technical Support.

44

6192

Course program:
Invalid jump target

< 5 msec

ю ю ¨ ¨

l

The digital inputs for START1 & START2
have been set at the same time.

l

Impermissible jump
target/impermissible target position has
been selected.

55

8100

CAN communication
error

< 5 msec

ю ю ю ¨

l

Communication is interfered

l

Double nodes in network

l

Check installation with regard to EMC.

l

Check baud rate setting

l

Check node number setting

56

7510

RS232 communication
error

< 5 msec

ю ю ю ¨ Communication is interfered

Check installation with regard to EMC.

57

6191

Position data record
error

< 5 msec

þ ¨ ¨ ¨ Conflict between acceleration and selected

traversing speed.

Please contact the Technical Support.

58

6380

Faulty operating mode

< 5 msec

ю ю ю ¨ Faulty operating mode

Change operating mode when power stage is
switched on.

Advertising