4 analog outputs amon, Analog outputs amon – Lenze 931E/K Small Drives Control User Manual

Page 114

Advertising
background image

Digital outputs and analog inputs and outputs

Analog outputs AMON

7

l

114

SW−HB 13.0002−EN 4.1

7.4

Analog outputs AMON

The 931E servo positioning controller has two analog outputs for the output and display
of internal control values which can be displayed by using an external oscilloscope. The
output voltage is between 0 V and +10 V. The resolution is 8 bits.

The 931K servo positioning controller has one analog output for the output and display of
internal control values. The output voltage and the resolution are the same as for the 931E
servo positioning controller.

Select the menu items Parameters

W I/Os W Analog outputs to configure the analog

monitor.

931e_328

You can select between different values. Select the value to be displayed by the analog
monitor.

Select the scaling in the Scaling field. The units will be automatically adapted when the
value to be displayed is changed.

In the Offset field, you can select an offset voltage to display, for instance, positive and
negative values.

If the Numeric overflow limitation box is checked, all calculated values that are higher than
+10 and lower than 0 V will be limited to these values. If the box is not activated, values
exceeding the +10 V−value will be indicated as voltages starting from 0 V and vice versa.

)

Note!

The option "Freely selectable communication object" is reserved for special
applications. You can also display and check other internal controller values for
analysis purposes.

Advertising