Parameterisation of outside motors
Direct entry of distance, speed and acceleration units

10

l

154

SW−HB 13.0002−EN 4.1

10.1.13

Direct entry of distance, speed and acceleration units

Direct input

If you have selected the option Direct input in the Display mode field in the Display units
tab, you can directly enter the Position, Speed and Acceleration factor group in the Direct
input tab.

(

Stop!

For experienced users only!
Through the direct entry of the physical units you can radically change the
control parameters of the 931E/K servo positioning controller.

You can select the following units for the display of the parameter setting program:

ƒ

Increments

ƒ

Degrees

ƒ

Radians

ƒ

Revolution

ƒ

Metres

ƒ

Millimetres

ƒ

Micrometres

ƒ

User−defined

ƒ

No unit