Digital outputs and analog inputs and outputs
Digital outputs DOUT1, DOUT2
l
109
SW−HB 13.0002−EN 4.1
Destination
ƒ
Angle/distance:
Tolerance margin in which the message "Target reached" is set.
ƒ
Message delay:
Time delay, in which the actual position must be within the tolerance window, before
the message "Target reached" will be set.
931e_322
Motor speed message
ƒ
Declared speed:
Speed at which the message "Declared speed reached" will be set.
ƒ
Message window:
Tolerance margin, in which the actual speed must be around the declared speed to
ensure that the message "Declared speed reached" will be set.