Dr – v42 bis data compression report – Westermo GDW-11 User Manual

Page 144

Advertising
background image

144 Data commands

6615-2220

+DR – V42 bis data compression report

Description:

This command determines whether or not the use of V42bis is allowed for an incoming
or outgoing data call, if the feature is provided by the product.

The intermediate result code represents current DCE-DCE data compression type. The
format of this result code is as follows:

+DR: NONE

Data compression is not in use

+DR: V42B

Rec. V.42-bis is in use in both directions

+DR: V42B RD

Rec. V.42-bis is in use in receive direction only

+DR: V42B TD

Rec. V.42-bis is in use in transmit direction only

The +DR intermediate result code, if enabled, is issued before the final result code, after
the service report control +CR and before the +ILRR intermediate report.

Syntax:

AT+DR=<status>

Parameters:

<status>

State of the V42bis enabling

0:

disabled (default value)

1: enabled

Command example

Possible responses

Note

AT+DR=? +DR:

(0.1)

OK

AT+DR=1 OK

Reporting

enabled

AT+DR?

+DR: 1

Current value

OK