Wcbpwd – callback/secure access password – Westermo GDW-11 User Manual

Page 257

Advertising
background image

Callback security commands – only in GDW-12 257

6615-2220

Command example

Possible responses

Note

AT*WCB=2 OK

Callback

enabled

AT*WCB?

*WCB: 2

Check current value

OK

*WCBPWD – callback/secure access password

Description:

This command is used to store the password used in the callback and the secure access
functionality.

Three different passwords can be stored.

Syntax:

AT*WCBPWD1=<pwd>

AT*WCBPWD2=<pwd>

AT*WCBPWD3=<pwd>

Parameters:

<pwd>

The password may contain any writable character. The maximum number of characters is
20.

See also the following commands: *wcbtab, *wcb, capawcbtime

Command example

Possible responses

Note

AT*WCBPWD1=qwerty

OK

Set password no 1

AT*WCBPWD2=asdfgh

OK

Set password no 2

AT*WCBPWD3=zxcvbnm

OK

Set password no 3

AT*WCBPWD1?

*WCBPWD1: qwerty

Current value

AT*WCBPWD3=-

OK

Delete the password

Advertising