Wdr – data rate – Westermo GDW-11 User Manual
Page 183

Specific AT commands 183
6615-2220
+WDR – Data Rate
Description:
This command allows the data rate for bearer data to be configured for outgoing and
incoming calls.
Syntax:
AT+WDR=<out_coding_type>[,<in_coding_type>]
AT+WDR=[<out_coding_type>],<in_coding_type>
Response Syntax:
+WDR: <out_coding_type>,<in_coding_type>
NOTE:
<out_coding_type> is related to outgoing calls, and <in_coding_type> to incoming calls.
Parameters:
<out_coding_type>
0: FR
1:
HR, other supported types: FR
2:
FR, other supported types: HR
<in_coding_type>
0: HR
1: FR
Command example
Possible responses
Note
AT+WDR=?
+WDR: (0-2),(0-1)
If Half Rate available in
OK both
directions
AT+WDR=?
+WDR: (0),(1)
If Half Rate not available.
OK
AT+WDR=1 OK
Configure data type FR,
HR with HR preferred, for
outgoing calls (<in_cod-
ing_type> parameter is
omitted)
AT+WDR=,1 OK
Configure data type FR for
incoming calls (<out_cod-
ing_type> parameter is
omitted)
AT+WDR=3
+CME ERROR: 3
Illegal value
AT+WDR?
+WDR: 1,1
Ask for the current value
OK