Westermo GDW-11 User Manual

Page 206

Advertising
background image

206 Specific AT commands

6615-2220

Parameter Type

MCC-MNC 3

bytes

LAC 2

bytes

CI 2

bytes

Network measurement

16 bytes

BCCH channel list

Maximum 48 bytes (if version V0 of GSM Rec 11.14-800 )
Or 129 bytes (if version V1 of GSM Rec 11.14-800). The
version number in indicated in TERMINAL PROFILE infor-
mation in EEPROM. It is not user-customizable. It is config-
ured at production-time.

Timing Advance

1 byte

Date and Time

7 bytes: Date, time and time zone at STLK Format

For mode = 3:

<dump>

(Optional parameter)

Range: [1-255] (at least 1 bit set to 1).
-if bit 0 set to 1 (value 1):

DaT will be returned in the response

-if bit 1 set to 1 (value 2):

TA will be returned in the response

-if bit 2 set to 1 (value 4):

BCCH will be returned in the response

-if bit 3 set to 1 (value 8):

NetMeas will be returned in the response

-if bit 4 set to 1 (value 16): CI will be returned in the response
-if bit 5 set to 1 (value 32): LAC will be returned in the response
-if bit 6 set to 1 (value 64): MNC-MCC will be returned in the response

NOTE:

… After having downloaded the EEPROM configuration: default value of <dump>

is 0xFF (all information returned).

… The <dump> value set with the command “at+wloc= 3,xx” is saved in EEPROM,

so it will be taken into account after an Init.

… See Appendix C for details on BCCH channel list.

Command example

Possible responses

Note

AT+WLOC=0 OK

Stops the display of local
information

AT+WLOC=3,255 OK

Set the wished information
to display (255 -> com-
plete information)

AT+WLOC=1

+WLOC: 02f802,0006,

Displays once the local

7772,

f13101b04cf51278

information

91138e95a846d160,
8b49d08d0797c419e
272e10889a000009302
170399020403c1020a03c

5020a03,

00,010121111349ff

OK

AT+WLOC=2,6

+CME ERROR:3

6 is not a multiple of 5

Advertising