At+wolm – operator list management – Westermo GDW-11 User Manual

Page 38

Advertising
background image

38 Network service commands

6615-2220

Command example

Possible responses

Note

AT+CREG=0 OK

Disable network registra-
tion unsolicited result code,
Command valid

AT+CREG=1 OK

Enable network registra-
tion unsolicitedresult code,
Command valid

AT+CREG=2 OK

Enable network registration
and location information
unsolicited result code,
Command valid

AT+CREG=? +CREG:

(0-2)

0,1,2 <mode> values are
supported

AT+WOLM – Operator List Management.

Description:

This command allows a new or modified operator to be added to the PLMN list.
At most 10 PLMN can be created and stored in the flash memory.

Please note that if two entries with the same network (MCC + MNC), but have different
names, are entered, the first one will be taken into account to have the name.

Syntax:

AT+WOLM=<mode>,<loc>[,<NumOper>,<short name>,<long name>]

Response Syntax:

AT+WOLM?

+WOLM: <loc>,<NumOper>,<short name>,<long name>

+WOLM: ...

Parameters:

<mode>

0: delete
1:

write

2: read

<loc>

Location. If this parameter is not filled with <mode>=1, the location will be the first
empty

<NumOper>

Operator in numeric format.

<short name>

The short name of the PLMN.