Westermo GDW-11 User Manual
Page 21
Advertising

General commands 21
6615-2220
+CMEC – Mobile equipment control mode
Description:
This command sets ME indicators. If operation mode is not allowed by the ME, +CME
ERROR: <err> is returned
Syntax:
AT+CMEC=[<keyp>[,<disp>[,<ind>]]]
Response syntax:
+CMEC: <keyp>,<disp>,<ind>
Parameters:
<keyp>
reserved
<disp>
reserved
<ind>
0:
only ME can set the status of its indicators (command +CIND can only be used to
read the indicators)
1:
only TE can set the status of ME indicators (with command +CIND)
2:
ME indicators can be set by both ME and TE
Command example
Possible responses
Note
AT+CMEC? +CMEC:
2,0,0
OK
AT+CMEC=? +CMEC:
(2),(0),(0)
OK
no change allowed