Wiot – generic i/o test – Westermo GDW-11 User Manual

Page 253

Advertising
background image

I/O commands – only in GDW-12 253

6615-2220

Command example

Possible responses

Note

AT*WIOL=4?

4_Service=TRANS

List the entry table:

4_Flag=RETRY

List entry 4

4_Timeout=040
4_Priority=YES
4_Data1=016428250
4_Data2=
4_Data3=
4_Data4=
4_Data5=
4_Data6=

*WIOT – Generic I/O test

Description:

This command executes the specified entry as if it was trigged by the normal trigger
condition.

Syntax:

AT*WIOT =<entry_num>[,<IO_state>]

Parameters:

<entry_num>

IO entry index number (0 – 10) 1 – 10 selects the entry at the corresponding index
in the table. Selecting entry_num =0 selects the local output, the state of the output is
selected with parameter I/O_state

<IO_state >

The state to set the local output ( 0 or 1) when entry_num is set to 0.

Command example

Possible responses

Note

AT*WIOT =2

OK

Trigger and execute entry
2 in the table

AT*WIOT =?

*WIOT: (0-10)[,(1-1)]

OK