Wiop – generic i/o parameters – Westermo GDW-11 User Manual

Page 254

Advertising
background image

254 I/O commands – only in GDW-12

6615-2220

*WIOP – Generic I/O parameters

Description:

This command set the I/O parameters.

Syntax:

AT*WIOP=<tmin>,<tmax>,<type>,<trig>,<norm>

Parameters:

<tmin>

Min trig pulse time in 10 ms increments [1-255].

This parameter sets the minimum time the pulse must be active. A pulse shorter than
this time will be skipped.

<tmax>

Max trig pulse time in 10 ms increments [1-255]

Sets the maximum active with of a pulse, if pulse is longer the pulse will be skipped.

The number of pulses will be calculated when the time between pulses is longer than
3 times tmin.

<type>

Trig source and type according to the table below:

0:

NO, Trigger not used

1:

LEVEL, Trigger source is the Digital input Level

2:

PULSE, Pulsed trigger used

3:

DCD, Trigger internally coupled to reflect the DCD signal

4:

DTR, Trigger internally coupled to reflect the DTR signal

<trig>

Trigger level.

0:

NO, Trigger not used

1:

HIGH, Defines that a High level triggers the service

2:

LOW, Defines that a Low level triggers the service

3:

POS, A positive edge triggers the service.

4:

NEG, A negative edge triggers the service.

<norm>

The source controlling the output.

0:

NO, Output not used

1:

IO operation, Controlled by remote I/O Transparent or Out

2: Reserved
3:

DCD, Output will be controlled by DCD. An active DCD will activate the output.

4:

DTR, Output will be controlled by DTR. An active DTR will activate the output.

Advertising
This manual is related to the following products: