Westermo GDW-11 User Manual

Page 250

Advertising
background image

250 I/O commands – only in GDW-12

6615-2220

OUT:

Phone number of the modem where the output shall be set. If <data1>, is
empty the transfer will be to the local digital output.

CMD:

AT command string to be executed when the entry is trigged, can be used
to modify the trigger condition

TRANS:

Phone number of the modem to which the transparent I/O should occur.
For dependencies of other parameters and line type, Please See Table 1
… <data1>=number

Makes a connection to the number defined and start Transparent I/O
transfer between the two units.

<data1>=empty
Transparent I/O transfer will use an existing data connection.

<data2>

Interpretation of field <data2> is also service dependent the size is 0 – 160 characters.

DIAL: Not

used

SMS:

The SMS message

TEXT: Text

message

EMAIL: E-mail

message

OUT:

A sequence of “101.. “ to be transferred to the addressed output

CMD: Not

used

TRANS: Not used

<data3>

Field <data3> is only used for SMS and EMAIL service.

The content of <data3> in each service is described below.

SMS:

SMS provider number.

EMAIL: Reserved for ISP number

<data4>

Field <data4> is only used for SMS and EMAIL service.

The content of <data4> in each service is described below.

SMS:

SMS protocol. 0 = No protocol, 1= UDP, 2 = TAP

EMAIL: Reserved for email protocol

<data5>

Field <data5> is only used for SMS and EMAIL service.

The content of <data5> in each service is described below.

SMS:

Password for access to SMS provider

EMAIL: Reserved for password to mail server

<data6>

Field <data6> is only used for EMAIL service. The content of <data6> is described below.

EMAIL: Reserved for username to mail server

Advertising