16 General commands

6615-2220

+CALA – Alarm Management

Description:

This command is used to set alarms date/time in the ME.
The maximum number of alarms is 16.
Seconds are not taken into account.

Syntax:

AT+CALA=<date and time string> (set alarm)

AT+CALA=””,<index> (delete alarm)

Parameters:

<date and time string> is a string with the following format: “yy/MM/dd,hh:mm:ss”

see +CCLK

<index>

is a number from 1 to 16.

Command example

Possible responses

Note

AT+CALA=”00/06/09,

OK

Set an alarm for June 9th,

07:30”

2000 at 7:30 am,
Alarm stored

AT+CALA=”99/03/05,

+CME ERROR 3

Invalid alarm

13:00:00”

(date/time

expired)

AT+CALA?

+CALA: “00/06/08,15:25:00”,1

List all alarms

+CALA: “00/06/09,07:30:00”,2

Note: three alarms are set

+CALA: “00/06/10,23:59:00”,3

(index 1, 2, 3)

+CALA: “00/06/08,15:25:00”,1

An alarm occurs (index 1)

AT+CALA=””,2

OK

Delete alarm index 3

AT+CALA? +CALA:

“00/06/09,07:30:00”,1

List all alarms, Only one
alarm (index 2)

Advertising