Yaskawa PC NC User Manual

Page 151

Advertising
background image

3 - 94

YASNAC PCNC Operating Manual

Chapter 3: HMI Process Operation

FIGURE 3.7.20.1. The CNC Tab of the Switch Label Screen

The Machine tab, shown in Figure 3.7.20.2 on page 95, can be used by machine tool builders to
create a software version of the CNC pendant panel in the Machine Switches box of the Run:NC
Switch
screen. For each switch shown, there is a label, output keep relay address (Switch Address
and Switch Bit) and LED output keep relay address (Lamp Address and Lamp Bit). All of these
fields are editable. The list can contain a maximum of 16 machine switches. A switch is displayed
if its Enabled box is checked.

Clicking the Delete Switch button while a line in the table is selected will remove that
line from the table.

Advertising