Yaskawa PC NC User Manual

Page 171

Advertising
background image

4 - 9

YASNAC PCNC Operating Manual

Chapter 4: Maintenance

(10)Alarm Nos.: 3081 to 3088 (Broken PG Cable)

The A and B phase signal cables are checked for breakage.

(11)Alarm No. 3091 (Broken Spindle PG Cable)

The A, B, and C phase signal cables are checked for breakage.

(12) Alarm Nos.: 3121 to 3125 (Excessive Speed)

This alarm is detected if the motor speed exceeds 1.2 times the maximum motor speed.

Contact your Yaskawa representative.

Table 4.1.5.7: Troubleshooting – Alarm Nos.: 3081 to 3088 (Broken PG Cable)

CAUSE CHECK

ITEM

COUNTERMEASURES

Signal cables between the

NC and the AC servo drive

unit are broken or loose.

Make sure that the cable connectors are
plugged into the connectors securely.

If they are loose or disconnected,

re-connect them correctly.

Faulty PG cable

breakage detection

circuit.

Check if the alarm occurs in the first

pressing of POWER ON button even

if the cables are connected correctly.

Contact your Yaskawa

representative.

Error in motor type

parameter setting

Check the motor type setting parameters
(pm 1061 to pm 1065) if “0” has been set.

Correct the setting for the motor
type setting parameters (pm1061
to pm1065).

Table 4.1.5.8: Troubleshooting – Alarm No.: 3091 (Broken Spindle PG Cable)

CAUSE CHECK

ITEM

COUNTERMEASURES

Signal cables between the

NC and the AC servo drive

unit are broken or loose.

Make sure that the cable connectors are

plugged into the connectors securely.

If they are loose or disconnected,

re-connect them correctly.

Faulty PG cable breakage -

detection circuit

Check if the alarm occurs in the first

pressing of POWER ON button even

if the cables are connected correctly.

Contact your Yaskawa

representative.

Faulty PG

If an alarm occurs during low speed

operation, the PG could be faulty.

Contact your Yaskawa

representative.

Advertising