Maximum feedrate for handle operation, Acceleration/deceleration time constant, Parameters pm2561 to pm2565 – Yaskawa PC NC User Manual
Page 180: Parameter pm2549
Advertising
4 - 18
YASNAC PCNC Operating Manual
Chapter 4: Maintenance
(e) Other related parameters
Check the setting for the following parameters.
(3) Jog Operation is Impossible
(a) Jog mode signal is not input
Check the bit status of I/O monitor #3000.
Dl = l
Other bits (DO, D2 to D7) = O
(b) Axis move direction signal is not input.
Check the bit status of I/O monitor #3071 and #3072.
Maximum feedrate for handle operation
Parameter pm2860 (linear axis)
Parameter pm2861 (rotary axis)
Acceleration/deceleration time constant
Parameters pm2561 to pm2565
Pulse multiplication ratio of “×100” is set (pm2003 D7 = 1)
Parameter pm2549
#3071
#3072
D0
+1st axis
D0
-1st axis
Dl
+2nd axis
Dl
-2nd axis
D2
+3rd axis
D2
-3rd axis
D3
+4th axis
D3
-4th axis
D4
+5th axis
D4
-5th axis
Advertising