YASNAC PCNC Operating Manual

Chapter 4: Maintenance

(e) Other related parameters

Check the setting for the following parameters.

(3) Jog Operation is Impossible

(a) Jog mode signal is not input

Check the bit status of I/O monitor #3000.

Dl = l

Other bits (DO, D2 to D7) = O

(b) Axis move direction signal is not input.

Check the bit status of I/O monitor #3071 and #3072.

Maximum feedrate for handle operation

Parameter pm2860 (linear axis)

Parameter pm2861 (rotary axis)

Acceleration/deceleration time constant

Parameters pm2561 to pm2565

Pulse multiplication ratio of “×100” is set (pm2003 D7 = 1)

Parameter pm2549

#3071

#3072

D0

+1st axis

D0

-1st axis

Dl

+2nd axis

Dl

-2nd axis

D2

+3rd axis

D2

-3rd axis

D3

+4th axis

D3

-4th axis

D4

+5th axis

D4

-5th axis