A3 - 141
YASNAC PCNC Operating Manual
APPENDIX 3: Parameter Tables
Screen
Address
Bit
Description
Register
Units
Minimum
Value
Maximum
Value
Long Description
3002
0
Clearing MDI buffer at comple-
tion of MDI program
0
1
Clearing MDI buffer
by program reset if
M02 or M30 is speci-
fied at the completion
of MDI program
1
Clearing MDI buffer by reset
operation
0
1
2
Start position of MDI program
0
1
3004
6
Work
pos
, Work shift, Tool off
change in EDT LOCK
0
1
3005
1
Clearing of the program numbers
at power ON
0
1
4
Auto edit of program number
when
0
1
3007
2
Program upload operation during
EDIT LOCK
0
1
3
Program download operation
during EDIT LOCK
0
1
4008
0
Rewind execution pointer when
external reset
0
1
3
Starting memory operation from
a block midpoint
0
1
7
High-speed automatic start for
high-speed rewind
0
1
4024
0
1st axis validity of playback write
0
1
1
2ndt axis validity of playback
write
0
1
2
3rd axis validity of playback write
0
1
3
4th axis validity of playback write
0
1
4024
4
5th axis validity of playback write
0
1
4025
5
Validity of playback F command
write
0
1
6
Validity of playback S command
write
0
1
7
Validity of playback T command
write
0
1