Table 4.1.7.1: i/o monitor and feedrate override – Yaskawa PC NC User Manual

Page 186

Advertising
background image

4 - 24

YASNAC PCNC Operating Manual

Chapter 4: Maintenance

If it is” 1”, check whether the spindle is in the speed agreed status by I/O monitor #3111.

(b) FEEDRATE OVERRIDE switch setting is 0%.

Check the setting for I/O monitor #311 1 D0 to D4 whether the setting is correct.

(c) ln the dry run mode, setting for jog feedrate is incorrect.

Table 4.1.7.1: I/O Monitor and Feedrate Override

I/O MONITOR #3040

FEEDRATE OVERRIDE

(AUTOMATIC OPERATION)

D4

D3

D2

D1

D0

OV16

OV8

OV4

OV2

OV 1

0

0

0

0

0

0%

0

0

0

0

1

10%

0

0

0

1

0

20%

0

0

0

1

1

30%

0

0

1

0

0

40%

0

0

1

0

1

50%

0

0

1

1

0

60%

0

0

1

1

1

70%

0

1

0

0

0

80%

0

1

0

0

1

90%

0

1

0

1

0

100%

0

1

0

1

1

110%

0

1

1

0

0

120%

0

1

1

0

1

130%

0

1

1

1

0

140%

0

1

1

1

1

150%

1

0

0

0

0

160%

1

0

0

0

1

170%

1

0

0

1

0

180%

1

0

0

1

1

190%

1

0

1

0

0

200%

1

0

1

0

1

220%

1

0

1

1

0

240%

1

0

1

1

1

260%

1

1

0

0

0

280%

1

1

0

0

1

300%

1

1

0

1

0

340%

1

1

0

1

1

380%

1

1

1

0

0

420%

1

1

1

0

1

460%

1

1

1

1

0

500%

1

1

1

1

1

540%