1 - 11

YASNAC PCNC Operating Manual

Chapter 1: Outline of YASNAC System

(

2) Stored Stroke Limit B, C (G22, G23) *

The area either outside or inside the boundary set by parameters or by the commands in a

program is established as the entry prohibited area. The boundary is set with the coordi-
nate values in the machine coordinate system. Whether the entry prohibited area is estab-
lished outside or inside the boundary can be determined by the setting for a parameter.
The function is made valid upon completion of the reference point return after turning ON
the power.

FIGURE 1.2.3.2: Stored Stroke Limit B Function

•

In addition to the stored stroke limits A and B, stored stroke limit C can be added.

•

With the stored stroke limit C, set the boundary of the area and inside or outside the
boundary by parameters.

•

According to the setting for the parameter or the input signal, one of the stored stroke
limit C (third to fifth prohibited area) can be made valid.

•

For details of the stored stroke limit B, C, refer to 4.2.3 “Stored Stroke Limit B and C
(G22, G23)” in the PROGRAMMING MANUAL.

Table 1.2.3.1: G Code Used to Turn ON/OFF the Stored Stroke Limit B Function

G CODE

FUNCTION

GROUP

G22

Turning ON the stored stroke limit B

04

G23

Turning OFF the stored stroke limit B

04