Using the feed cutting timer – Yaskawa PC NC User Manual
Page 92
3 - 35
YASNAC PCNC Operating Manual
Chapter 3: HMI Process Operation
• Switch to the Run:Timers screen.
• Touch the Reset
button for Cycle Start Timer to set it to 00:00:00.
• Press Cycle Start; the timer will start to count up.
• Press Feed Hold; the timer will stop.
• Press Cycle Start again; the timer will continue counting from its previous value.
Using the Feed Cutting Timer:
• Using the File:Editor screen, create and save the following program:
O00001
G20
G90
G00X100.
X0.
G01X1.F10.
M30
• Set The NC to memory
mode.
• Set O00001 to be the current program.
• Switch to the Run:Timers screen.
• Touch the Reset
button for Feed Cutting Timer to set it to 00:00:00.
• Press Cycle Start. The feed cutting timer does not change until the NC executes the G01
block. At that point, when “F” status is displayed on the screen, the Feed Cutting Timer
will start to count up.