Yaskawa PC NC User Manual

Page 168

Advertising
background image

4 - 6

YASNAC PCNC Operating Manual

Chapter 4: Maintenance

(2) Alarm Nos.: 2061 to 2068 (Reference Point Return Area Error)

(3) Alarm Nos.: 2071 to 2078, 2081 to 2088

(Reference Point Return Position Error)

Table 4.1.5.2: Troubleshooting - Alarm Nos.: 2061 to 2068 (Reference Point Return Area Error)

CAUSE CHECK

ITEM

COUNTERMEASURES

The reference

point return start

point is at the

zero point side of

the deceleration

limit switch.

Deceleration limit switch (DECLS)

If reference point return is started from a point

located at the reference point side of DECL

(point C) as shown below, an alarm occurs.

Note: This error check is not made before the execution

of manual reference point return after the power
is turned ON.

Return the axis to a position on the

deceleration LS or away from it

and, then, execute reference

point return once again.

Approach

feedrate is

too fast.

Compare the setting for the approach

feedrate parameter with the parameter list.

Change the setting for

parameters pm2521 to pm2525

to an appropriate value.

Table 4.1.5.3: Troubleshooting – Alarm Nos.: 2071 to 2078, 2081 to 2088 (Reference Point Return

Position Error)

CAUSE CHECK

ITEM

COUNTERMEASURES

Alarm in manual reference

point return operation

Check if the error occurs every time.

Contact machine tool builder or

your Yaskawa representative.

Alarm in automatic reference

point return operation

G28: Check if the alarm occurs every time.

Contact machine tool builder or

your Yaskawa representative.

G27: Check the point specified in the program

if it agrees with the zero point.

Review the program.

#3073 DO (1st axis)
#3073 D1 (2nd. axis)
#3073 D2 (3rd axis)
#3073 D3 (4th axis)
#3073 D4 (5th axis)

Execute reference
point return again
while observing the
I/O signal monitor
screen

Advertising