A2 - 21, Alarm no. : 1099 high temperature – Yaskawa PC NC User Manual
Page 232
A2 - 21
YASNAC PCNC Operating Manual Appendix 2: Alarm Tables
2.3 TROUBLESHOOTING
Alarm No. : 1098 Fan is Faulty
ALARM CAUSE
CHECK ITEM
COUNTER MEASURE
Fan is faulty.
Check fan. Ensure connections are
If the fan is faulty, replace it. Contact your
good. Check for obstruction.
Yaskawa representative.
Alarm No. : 1099 High Temperature
ALARM CAUSE
CHECK ITEM
COUNTER MEASURE
Ambient temperature of the NC rack
Open NC door and check that the cooling
If the fan is faulty, replace it. Contact your
exceeded the specified value* due to
fan motor is operating.
Yaskawa representative.
cooling fan failure.
Make sure that air is blowing out through
the ventilation port of the cooling duct.
If cooling fan is block remove obstruction.
* : 70 degC +/- 3 degC
Check to make sure ventilation port of
When measured above CPS-18
cooling duct is not obstructed.
Allow the power supply unit to cool by
Internal temperature of the power supply
turning OFF the power with the NC unit
Change the power supply unit. Contact
unit is high.
door opened. If the alarm occurs even
your Yakawa representative.
after the power supply unit has been
cooled for 30 minutes, the power supply
unit is faulty.
Ambient temperature of the NC unit is high.*
Measure ambient temperature.
This is not the failure of the NC unit.
Remove the cause.
* Allowable temperature range for
If the NC unit is subject to direct sunlight,
‘operation is 0 - 40 degC.
the NC unit temperature will exceed the
allowable limit.