4 - 21

YASNAC PCNC Operating Manual

Chapter 4: Maintenance

if the setting for the parameters is correct.

For the 6-step specification (pm2000 D3 = 1) refer to Table 4.1.7.3.

(d) Parameter setting is incorrect

Refer to Tables 4.18 and 4.19

Table 4.1.7.2: Input Status and Rapid Traverse Rate

INPUT STATUS

OF #3003

RAPID TRAVERSE RATE

ROV2

ROV1

1st axis

2nd axis

3rd axis

4th axis

5th axis

1

1

Set for

pm2801

Set for

pm2802

Set for

pm2803

Set for

pm2804

Set for

pm2805

1

0

[Set for

pm2801]

× 1/2

[Set for

pm2802]

× 1/2

[Set for

pm2803]

× 1/2

[Set for

pm2804]

× 1/2

[Set for

pm2805]

× 1/2

0

1

[Set for

pm2801]

× 1/4

[Set for

pm2802]

× 1/4

[Set for

pm2803]

× 1/4

[Set for

pm2804]

× 1/4

[Set for

pm2805]

× 1/4

0

0

F

0

(set for pm2447)

Table 4.1.7.3: Input Status and Rapid Traverse Rate

INPUT STATUS

RAPID TRAVERSE RATE

ROV4

ROV2

ROV1

1st to 5th Axis I

1

0

1

F

2

(set for prn2449)

1

0

0

F

1

(set for pm2448)

0

1

1

100%

0

1

0

50%

0

0

1

23%

0

0

0

F

0

(set for pm2447)