Set for pm2801, Set for pm2802, Set for pm2803 – Yaskawa PC NC User Manual
Page 183: Set for pm2804, Set for pm2805, Set for pm2801] ° 1/2, Set for pm2802] ° 1/2, Set for pm2803] ° 1/2, Set for pm2804] ° 1/2, Set for pm2805] ° 1/2
4 - 21
YASNAC PCNC Operating Manual
Chapter 4: Maintenance
if the setting for the parameters is correct.
•
For the 6-step specification (pm2000 D3 = 1) refer to Table 4.1.7.3.
(d) Parameter setting is incorrect
Refer to Tables 4.18 and 4.19
Table 4.1.7.2: Input Status and Rapid Traverse Rate
INPUT STATUS
OF #3003
RAPID TRAVERSE RATE
ROV2
ROV1
1st axis
2nd axis
3rd axis
4th axis
5th axis
1
1
Set for
pm2801
Set for
pm2802
Set for
pm2803
Set for
pm2804
Set for
pm2805
1
0
[Set for
pm2801]
× 1/2
[Set for
pm2802]
× 1/2
[Set for
pm2803]
× 1/2
[Set for
pm2804]
× 1/2
[Set for
pm2805]
× 1/2
0
1
[Set for
pm2801]
× 1/4
[Set for
pm2802]
× 1/4
[Set for
pm2803]
× 1/4
[Set for
pm2804]
× 1/4
[Set for
pm2805]
× 1/4
0
0
F
0
(set for pm2447)
Table 4.1.7.3: Input Status and Rapid Traverse Rate
INPUT STATUS
RAPID TRAVERSE RATE
ROV4
ROV2
ROV1
1st to 5th Axis I
1
0
1
F
2
(set for prn2449)
1
0
0
F
1
(set for pm2448)
0
1
1
100%
0
1
0
50%
0
0
1
23%
0
0
0
F
0
(set for pm2447)