Appendix 2.1 pcnc classification of alarms, A2 - 2, No. contents stop mode output how to reset – Yaskawa PC NC User Manual

Page 213

Advertising
background image

A2 - 2

YASNAC PCNC Operating Manual Appendix 2: Alarm Tables

APPENDIX 2.1 PCNC CLASSIFICATION of ALARMS

No.

Contents

Stop Mode

Output

How to Reset

0000 - 0049

Errors related with edit and

operation. Occuring in the

background mode also.

Block Stop

Input error

alarm

RESET

0050 - 0099

Errors related with edit and

operation. Not occuring in

the background mode.

Block Stop

Input error

alarm

RESET

Power OFF for #0050 and # 0051

0100 - 0499

Program Error

(occuring in a series)

Block Stop

Input error

alarm

RESET

1000 - 1099

Program Error

(occuring over multiple series)

DNC, COMS total, etc….

Block Stop

Input error

alarm

RESET

2000 - 2199

Machine related error

OT, reference point return, machine

ready, in-position, etc…….

Stop after

deceleration, or
immediate stop

Alarm

Reset operation after removing the cause.
With the alarm caused by the mahine ready
signal, if it occurs in the first power ON opera-
tion, it is automatically reset.

3000 - 3299

Servo and spindle related alarm
ESP, CPU, mutual monitoring in NC.

Immediate stop

or servo off

Alarm

Reset after removing the cause. With the
SVOFF alarm, it is automatically reset by the
SVON.

8000 - 8049

Memory check error ( ROM,RAM )
Watchdog timer error
Offline error

Immediate stop

or servo off

Alarm

For maintenance
CPU Halt
Switching to the special maintenance screen

9000 - 9049

Errors related with edit and operation.
Occuring in the background mode also.

Not Stopped

Back-

ground

error

output

RESET or with reset softkey.

BAT.

indication

BAT.AXIS

Battery error
Encoder Alarm

Not Stopped

No output

Changing the battery

Warning

Message

Key operation error, edit operation
error ( Not serious operation error )

Not Stopped

Warning

Next key operation

Advertising