A3 - 155 – Yaskawa PC NC User Manual

Page 395

Advertising
background image

A3 - 155

YASNAC PCNC Operating Manual

APPENDIX 3: Parameter Tables

1653

3rd axis Variable in position check
No2 area

0.001mm

0

32767

For caned cycle and
solid tap

1654

4th axis Variable in position check
No2 area

0.001mm

0

32767

For caned cycle and
solid tap

1655

5th axis Variable in position check
No2 area

0.001mm

0

32767

For caned cycle and
solid tap

1671

1st axis torque limit value (+)

%

1

32767

1672

2nd axis torque limit value (+)

%

0

32767

1673

3rd axis torque limit value (+)

%

0

32767

1674

4th axis torque limit value (+)

%

0

32767

1675

5th axis torque limit value (+)

%

0

32767

1681

1st axis Servo Damping, observer
time constant

Hz

0

32767

1682

2nd axis Servo Damping, observer
time

Hz

0

32767

1683

3rd axis Servo Damping, observer
time constant

Hz

0

32767

1684

4th axis Servo Damping, observer
time constant

Hz

0

32767

1685

5th axis Servo Damping, observer
time constant

Hz

0

32767

1701

1st axis Servo Damping, load inertia
fine adjust

%

0

10000

1702

2nd axis Servo Damping, load
inertia fine adjust

%

0

10000

1703

3rd axis Servo Damping, load
inertia fine

%

0

10000

1704

4th axis Servo Damping, load
inertia fine adjust

%

0

10000

1705

5th axis Servo Damping, load
inertia fine adjust

%

0

10000

1751

1st axis Servo Damping, high pass
filter time const

micro sec

0

32767

1752

2nd axis Servo Damping, high pass
filter time const

micro sec

0

32767

1753

3rd axis Servo Damping, high pass
filter time const

micro sec

0

32767

1754

4th axis Servo Damping, high pass
filter time const

micro sec

0

32767

1755

5th axis Servo Damping, high pass
filter time const

micro sec

0

32767

1791

1st axis Servo Damping, low pass
filter time const

micro sec

0

32767

Address

Bit

Description

Register

Units

Minimum

Value

Maximum

Value

Long Description