Yaskawa PC NC User Manual

Page 374

Advertising
background image

A3 - 134

YASNAC PCNC Operating Manual

APPENDIX 3: Parameter Tables

Reference Point Return

Address

Bit

Description

Register

Units

Minimum

Value

Maximum

Value

Long Description

1044

5

1st axis Zero return Virtual C
phase motor 1 rev.
1: Use pm1851
0: Use pm1821

0

1

1045

5

2nd axis Zero return Virtual C
phase motor 1 rev.
1: Use pm1851
0: Use pm1821

0

1

1046

5

3rd axis Zero return Virtual C
phase motor 1
1: Use pm1851
0: Use pm1821

0

1

1047

5

4th axis Zero return Virtual C
phase motor 1 rev.
1: Use pm1851
0: Use pm1821

0

1

1048

5

5th axis Zero return Virtual C
phase motor 1 rev.
1: Use pm1851
0: Use pm1821

0

1

2521

1st axis reference point return
approach speed

mm/min,

deg/min

0

32767

2522

2nd axis reference point return
approach speed

mm/min,

deg/min

0

32767

2523

3rd axis reference point return
approach speed

mm/min,

deg/min

0

32767

2524

4th axis reference point return
approach speed

mm/min,

deg/min

0

32767

2525

5th axis reference point return
approach speed

mm/min,

deg/min

0

32767

2531

1st axis reference point return
creep speed

mm/min,

deg/min

0

32767

2532

2nd axis reference point return
creep speed

mm/min,

deg/min

0

32767

2533

3rd axis reference point return
creep speed

mm/min,

deg/min

0

32767

2534

4th axis reference point return
creep speed

mm/min,

deg/min

0

32767

2535

5th axis reference point return
creep speed

mm/min,

deg/min

0

32767

4001

6

Occurrence of Alarm cycle start
before Zero return
0: An alarm occurs
1: An alarm does not occur

0

1

Conforms to pm4018
d0-d4