Pm2001 d0 = 1, Pm2001 d0 = 0, Figure 4.1.11.1 – Yaskawa PC NC User Manual

Page 193

Advertising
background image

4 - 31

YASNAC PCNC Operating Manual

Chapter 4: Maintenance

(b) Parameter setting is incorrect.

•

Check the setting for parameter pm2001 DO. If the setting for pm2440 is “0”
while “pm2001 D0 = 1”, an axis does not move.

•

Check the setting for parameters pm5011 D0 to D2.

•

Set the signal status at the start of the processing when the SKIP signal is input.

FIGURE 4.1.11.1:

•

If “0”, processing starts at the point where 24 V faI1s to 0V.

•

After changing the setting, be sure to turn OFF the power once and turn it

ON again.

•

Check the setting for parameters pm5010 D0 to D0.

The setting for this parameter determines ENABLE/DISABLE of the control circuit
for the “SKIP” input.

•

Set “1” to use the skip function.

•

After changing the setting for this parameter always turn OFF the power - once

and then turn it ON again.

pm2001 D0 = 1

Feedrate in the skip feed mode (G31) is

the feedrate set for parameter pm 2440.

pm2001 D0 = 0

Feedrate in the skip feed mode (G31) is

the feedrate specified with an F code.