Pm2001 d0 = 1, Pm2001 d0 = 0, Figure 4.1.11.1 – Yaskawa PC NC User Manual

Page 193

Advertising
background image

4 - 31

YASNAC PCNC Operating Manual

Chapter 4: Maintenance

(b) Parameter setting is incorrect.

Check the setting for parameter pm2001 DO. If the setting for pm2440 is “0”
while “pm2001 D0 = 1”, an axis does not move.

Check the setting for parameters pm5011 D0 to D2.

Set the signal status at the start of the processing when the SKIP signal is input.

FIGURE 4.1.11.1:

If “0”, processing starts at the point where 24 V faI1s to 0V.

After changing the setting, be sure to turn OFF the power once and turn it

ON again.

Check the setting for parameters pm5010 D0 to D0.

The setting for this parameter determines ENABLE/DISABLE of the control circuit
for the “SKIP” input.

Set “1” to use the skip function.

After changing the setting for this parameter always turn OFF the power - once

and then turn it ON again.

pm2001 D0 = 1

Feedrate in the skip feed mode (G31) is

the feedrate set for parameter pm 2440.

pm2001 D0 = 0

Feedrate in the skip feed mode (G31) is

the feedrate specified with an F code.

Advertising