VDSL C

ONFIGURATION

10-10

PSD Breakpoints

See “Configuring Global Settings for VDSL Ports” on page 10-1.

PSD Mask Level

See “Configuring Global Settings for VDSL Ports” on page 10-1.

UPBO

See “Configuring Global Settings for VDSL Ports” on page 10-1.

Tone – Disables downstream or upstream VDSL signals at frequencies

less than or equal to 640 KHz, 1.1 MHz or 2.2 MHz. (Default: Disable
tones at 640 KHz and below)
This parameter specifies a frequency beneath which VDSL signals are
not allowed. For example, the default lower frequency bound for DS1
defined in Annex C of G.993.2 is 640 KHz. The low-end frequencies
filtered out by this parameter are used for common POTS or ISDN
services.
The frequency bound specified by this parameter takes precedence over
that defined in the selected band plan.

Data Rate – Specifies the minimum and maximum data rate for

downstream and upstream fast or slow (interleaved) channels.
(Default: 64 kbps minimum, 200,000 kbps maximum)
The parameter sets the minimum and maximum data rates supported by
each upstream and downstream band. Bounding data rates should be set
for both fast and slow channels if operation may sometimes disable or
enable interleaving. These bounds are applied to the specified interface
when rate adaption is enabled.

Max Power – Sets the maximum aggregate downstream or upstream

power. (Range: 0-255, in units of 0.25 dBm; Default:255, which is
equivalent to 63.75 dBm)

Min Protection – Configures the minimum level of impulse noise

protection for all bearer channels. This is expressed in the number of
consecutive DMT symbols for which errors can be completely corrected.
(Range: 0-255, in units of 0.5 DMT symbols, or 125 microseconds;
Default: 0)